3/8” and 1/2" NPT, BSPT
Inlet 400 Psig (28 Bar)
Description
The Generant Series CR Cryogenic Regulator provides high flow during Cryogenic Vessel Pressure Build function and increased sensitivity to downstream pressure changes as a function of our pre-formed all metallic diaphragm and optimized spring design. The unique diaphragm is unlike anything on the market today and results in less decrease in Cryogenic vessel pressure and faster recovery during periods of higher demand, thus decreasing the potential for flooding the pressure build coil. The unit features a 304 SS Inlet Strainer/Filter to aid in reducing contaminant related failures. Optional Cleaned and Packaged for Oxygen Service Series CR Regulators utilize Monel Inlet Strainer/Filters. All Series CR Cryogenic Regulators are 100% Factory Tested and are supplied factory pre-set.
![]() |
![]() |
| Resources |
|
|
|
|
| Additional Resources |
|
|
|
|
|
|
|
|
| Need Help ? |
|
|
|
|
Features
Materials of Constructions
Dimensional Data
Technical Data
Maximum Inlet Pressure: 400 Psi (28 Bar) Outlet Pressure Range: 0 to 235 Psi (0 to 16 Bar) Temperature Range: -320° to 225° F (78° to 380° K) Fail Open Cv: 3/8” NPT Ports – 2.4 1/2” NPT and BSPT Ports – 2.9
Flow Capacity
Flow Capacity is system dependent. For accurate flow capacity data, consult Generant with your specific system characteristics for more information.
How To Order
PROPER COMPONENT SELECTION - When specifying a component, the total system design must be considered to ensure safe and trouble-free performance. Intended component function, materials compatibility, pressure ratings, installation, environment and maintenance are the responsibility of the system designer.
Repair Kits
Includes:
PROPER COMPONENT SELECTION - When specifying a component, the total system design must be considered to ensure safe and trouble-free performance. Intended component function, materials compatibility, pressure ratings, installation, environment and maintenance are the responsibility of the system designer.
Replacement Spring Kits
Includes: Adjustment Screw and Spring Specify: CR-SK-500-A, 0-35 PSI Range CR-SK-500-B, 25-135 PSI Range CR-SK-500-C, 100-235 PSI Range Note: Adjustment Screws are sized according to Springs. Spring Code is engraved on the Adjustment Screw (A, B, C).
PROPER COMPONENT SELECTION - When specifying a component, the total system design must be considered to ensure safe and trouble-free performance. Intended component function, materials compatibility, pressure ratings, installation, environment and maintenance are the responsibility of the system designer.