Call us Today
(973) 838-6500| BI-Lok Tube Fittings | Cryogenic Products | Check Valves | Needle Valves | Quarter Turn Valves | Relief Valves | Regulators | Cryogenic Liquid Cylinder Accessories | Custom Solutions |
1/8" - 3/8" NPT
1/8" and 1/4" Dual Ferrule Tube
Vacuum - 5000 Psig (345 Bar)
Description
Series FNV Needle Valves feature a forged body, integral bonnet design with PTFE and metallic wafer stem packing. This provides leak-tite service from vacuum to the maximum operating pressure. Series FNV are available in Straight and Angle configurations, with NPT and Dual Ferrule Tube connections. The industry standard panel mounting allows the FNV to be a cost effective solution to many applications. Standard metal to metal stem and optional Soft Tip stem provide accurate metering over a wide range of pressures. The Series FNV can be ordered cleaned for Oxygen Service.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| Resources |
|
|
|
|
|
|
| Additional Resources |
|
|
|
|
|
|
|
|
| Need Help ? |
|
|
|
|
Features
Technical Data
Temperature / Pressure Ratings
| Temperature, °F (°C) | Max. Working Pressure, Psig (Bar) | ||
| Brass | 316 SS | ||
| - 320 (-195) to 100 (37) | 3000 (207) | 5000 (345) | |
| 100 (37) to 250 (93) | 2200 (151) | 4085 (281) | |
| 250 (93) to 350 (176) | 1470 (101) | 3715 (255) | |
| 350 (176) to 400 (204) | - | 3435 (236) | |
Testing
Every valve is factory tested with Nitrogen at 3000 Psig (207 Bar) for leakage. Maximum allowable seat leakage is 0.1cc/min.
Materials of Constructions
| Component | Brass | Stainless | |
| Valve Body | Brass, ASTM 377 | 316 SS, ASTM A182 | |
| Packing Nut | Brass, ASTM B16 | 316 SS, ASTM A479 | |
| Regulating Stem | 316 SS, ASTM A479 | ||
| Packing Washers | Brass, ASTM B36 | 316 SS, ASTM A479 | |
| Packing | PTFE, ASTM D1710 | ||
| Soft Stem Tip | PCTFE (Neoflon® M400), ASTM D1430 | ||
| Panel Nut | Brass, ASTM B16 | 303 SS, ASTM A582 | |
| Round Handle | Nylon 6/6 (Zytel®) with Brass Insert | ||
| "T" Handle | 303 SS, ASTM A582 | ||
| Handle Set Screw | 304 SS, ASTM A182 | ||
| Lubricant | Oxygen Compatible Perfluoropolyether (PFPE) Grease | ||
Dimensionsional Data
Flow Coefficient (Cv) @ Turns Open
Ordering Information
PROPER COMPONENT SELECTION - When specifying a component, the total system design must be considered to ensure safe and trouble-free performance. Intended component function, materials compatibility, pressure ratings, installation, environment and maintenance are the responsibility of the system designer.