Call us Today
(973) 838-6500| BI-Lok Tube Fittings | Cryogenic Products | Check Valves | Needle Valves | Quarter Turn Valves | Relief Valves | Regulators | Cryogenic Liquid Cylinder Accessories | Custom Solutions |
1/8" - 1/4" NPT
150 - 600 Psig
Description
A compact, highly accurate, direct acting pressure relief valve. Factory preset to desired crack pressure and/or flow specifications. Internal adjustment provides tamper proof safety against inadvertent pressure changes. Available in vent to atmosphere or inline configurations. Valves feature an encapsulated O-ring seal to prevent extrusion at higher differential pressures.
![]() |
![]() |
| Resources |
|
|
|
|
|
|
|
|
| Additional Resources |
|
|
|
|
|
|
|
|
| Need Help ? |
|
|
|
|
Features and Benefits
Technical Data
Materials of Constructions
| Component | Material |
| Valve Body, Stem, O-Ring Cup | Brass, ASTM B16 |
| Spring Retainer | 316 SS, ASTM A479 |
| Seal1 | As specified, see ordering information |
| Spring | 302 SS/17-7 PH, ASTM A313 |
| Locknut | 18-8 SS |
| 1 Lubricated with KrytoxTM | |
Dimensional Data
| Pipe Size NPT | VRVH | VRVHI | ||
| A | Hex | A | Hex | |
| 1/8" | 0.94 | 1/2" | 1.44 | 1/2" |
| 1/4" | 1.29 | 5/8" | 1.75 | 3/4" |
| Dimensional data is stated in inches | ||||
Flow Data, Series VRVH (Vent to Atmosphere)
| Nominal Spring | 150 | 250 | 500 | ||||
| Set Pressure Range (Psig) | 125 - 175 | 175 - 350 | 350 - 600 | ||||
| Valve Size | Orifice | Flow (SCFM) | Kd | Flow (SCFM) | Kd | Flow (SCFM) | Kd |
| 1/8" NPT (VRVH - 125) | 0.156 | 7.5 | 0.12 | 12.5 | 0.12 | 33 | 0.16 |
| 1/4" NPT (VRVH - 250) | 0.293 | 50 | 0.22 | 90 | 0.24 | 150 | 0.21 |
Flow Data, Series VRVHI (Inline)
| Nominal Spring | 150 | 250 | 500 | ||||
| Set Pressure Range (Psig) | 125 - 175 | 175 - 350 | 350 - 600 | ||||
| Valve Size | Orifice | Flow (SCFM) | Kd | Flow (SCFM) | Kd | Flow (SCFM) | Kd |
| 1/8" NPT (VRVHI - 125) | 0.156 | 12 | 0.18 | 13.5 | 0.13 | 35 | 0.17 |
| 1/4" NPT (VRVHI - 250) | 0.250 | 45 | 0.27 | 80 | 0.30 | 175 | 0.33 |
Ordering Information
PROPER COMPONENT SELECTION - When specifying a component, the total system design must be considered to ensure safe and trouble-free performance. Intended component function, materials compatibility, pressure ratings, installation, environment and maintenance are the responsibility of the system designer.
For Instructions on How to Select Your Model, click here.