The LTAP Series Low Temperature Actuation Probe is a temperature controlled pneumatic two-way valve. The device utilizes a pressurized copper probe which reacts to fluid temperature and opens a passageway in the top control head as the fluid temperature approaches the device temperature setpoint.
The LTAP Series can be installed on cryogenic systems to protect end users when draw rates are higher than system capacity or ambient conditions are much colder than normal. Factory pre-set at desired temperature — cannot be adjusted in the field.
- Highly Accurate: Setpoint tolerance of ±3°F
- Quick Open: Control head opens within -3°F from first bubble to full open
- Repeatable and Reliable: Activates at temperature setpoint repeatably across a wide range of ambient conditions
- Cleaned for O2 Service: Assembled cleaned for Oxygen Service as standard
- Robust Design: Solid brass construction with working pressures up to 600 PSIG (41 bar)
Note: This product is NOT a Safety Device or Safety Accessory.
- Maximum Probe Pressure: 600 PSIG (41.4 bar)
- Maximum Control Head Pressure: 600 PSIG (41.4 bar)
- Temperature Setpoint Range: -40°F to 0°F
- Setpoint Tolerance: Nominal ±3°F
- Full Open: Within -3°F of Initial Open
- Exposed Fluid Temperature Range: -320°F to +150°F
- Ambient Temperature Range: -60°F to +150°F
- Control Head Full Open Cv: 0.02
- Probe Connection: 1/2" NPT, Brass
- Control Head Connections: 1/8" NPT Inlet & Outlet
- Seal Options: EPDM (EP) or Fluorosilicone (FS)
Factory pre-set at desired temperature. Cannot be adjusted in the field. Do not attempt to disassemble.